◆ Integrated & standardized energy storage system, easy to transport, install and maintain
◆ Famous manufacturer provide LFP cells with good lifespan over 10 years
◆ Liquid cooling system, automatic balance management, effectively improve battery efficiency and life
◆ Unattended, convenient EMS access, online real-time system monitoring
◆ Support diesel generator access, switching between on-grid and off-grid (optional)
◆ Multiple working mode, suitable for various applications
◆ All-round real-time monitoring and energy optimization management, fully guarantee the safety of the battery system
◆ Three-phase 100% unbalanced load, strong load adaptability (optional)
◆ Modular design, support system expansion
10FT ESS:
Technical Specification | MQK-H10-100M1P | MQK-H10-100M2P | |||
Battery Type | LFP | ||||
Rated Charge/Dis charge Performance | <0.5C | ||||
Nominal Voltage [V] | 768 | ||||
Operating Voltage Range[V] | 672-876 | ||||
Cell Rated Capacity[Ah] | 280 | ||||
DC Side Nominal Capacity [KWh] | 215 | 430 | |||
Composition | (1P240S)*1P | (1P240S)*2P | |||
ACDATA | |||||
Rated Charge/Discharge Power[kW] | 100 | ||||
Max. AC Current[A] | 159 | ||||
Rated Output Voltage[V] | 400 | ||||
Rated Frequency[Hz] | 50/60 | ||||
THDU | <3%(Linear Load) | ||||
Unbalanced Load | 100% | ||||
GENERAL DATA | |||||
Ingress Protection | IP54 | ||||
Communication | CAN/RS485 | ||||
Communication Protocol | Modbus/IEC104 | ||||
Ambient Temperature [℃] | -25~+50 | ||||
PCS CoolingMethod | Temperature controlled smart fen cooling | ||||
Battery Cooling Method | Liquid cooling system | ||||
Fire Fighting System | 1230 fire fighting system | ||||
Delivery Method | Integral trans portation | ||||
Relative Humidity | 0~95%,no condensation | ||||
Weight[T] | 6.5 | 8.5 | |||
Dimension (W *D * H) [mm] | 2991*2438*2896 |
20FT BES:
Technical Specification MQK-G20-HV | |||||
BATTERY | |||||
Battery Type | LFP | ||||
Rated Charge/Discharge Performance | <0.5C | ||||
Nominal Voltage[V] | 133.2 | ||||
Operating Voltage Range[V] | 1040-1500 | ||||
Cell Rated Capacity [Ah] | 280 | ||||
DC Side Nominal Capacity[KWh] | 3354 | ||||
Composition | (1P416S)*9P | ||||
GENERAL DATA | |||||
Ingress Protection | IP54 | ||||
Communication | CAN/RS485 | ||||
Communication Protocol | Modbus/IEC104 | ||||
Ambient Temperature ["C] | -20~+50 | ||||
Battery Cooling Method | Liquid cooling system | ||||
Fire Fighting System | 1230 fire fighting system | ||||
Delivery Method | Integral transportation | ||||
Weight[T] | 30.5 | ||||
Dimension(W*D*H)[mm] | 6050*2440*2896 |